SMART SAFE OPER. SYSTEM ERROR1 (No., Information, )
A safety monitoring function error was detected. No. | Information | Cause --- | --- | --- 1 | | Safety watchdog error 2 | | Crosscheck error 3 | Function (*1) | Safety system internal processing error 4 | | Safety parameter saving memory error 1 5 | | Safety parameter saving memory error 2 6 | | Safety initial processing time-out 7 | Axis name | NC-DRV safety initial communication error 8 | Unit information | Safety I/O initial processing time-out *1 Function | Function name --- | --- 0001 | Safety limit speed monitoring (SLS) 0002 | Safety limit position monitoring (SLP) 0003 | Safety speed monitoring (SSM) 0004 | Safety cam (SCA) 0005 | Safety stop monitoring (SOS) 0006 | Safety stop 1 (SS1) 0007 | Safety stop 2 (SS2) 0008 | Safety torque stop (STO) 0009 | Safety brake control (SBC) 000A | Diagnosis function 000B | Safety related I/O monitoring
- 1Contact the nearest Mazak Technical Center or Technology Center.