CRITICALAlarm code
1005
SMART SAFE OPER. SYSTEM ERROR5 (No., Axis name, )
What it means
A safety monitoring function error was detected. No. | Cause --- | --- 1 | SLS speed error 2 | SLS deceleration error 3 | SLP position error 4 | SOS speed error 5 | SOS position deviation error 6 | SOS movement amount error 7 | SS1 deceleration error 8 | SS2 deceleration error
What to do
- 1Press the reset key.
- 2If the alarm is still not cleared, please contact the nearest Mazak Technical Center or Technology Center.
Codebook — decoded
EError typeNC Equipment — system hardware/software error
HStop statusEmergency stop — machine fully stopped
MClearingPower OFF → fix cause → Power ON
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.