CRITICALAlarm code
1020
SMART SAFE OPER. SYSTEM ALARM1 (No., Axis name, )
What it means
A safety monitoring function error was detected. No. | Cause --- | --- 1 | SSM hysteresis width setting error SSM hysteresis width is larger than SSM speed. 2 | Safety absolute position not established 1. The safety absolute position has not been established even once after making valid SLP/SCA. 2. In the encoder diagnosis performed while SLP/SCA power is off, there is a positional offset between the position saved when the power was turned off and the position restored when the power was turned on.
What to do
- 1Contact the nearest Mazak Technical Center or Technology Center.
Codebook — decoded
EError typeNC Equipment — system hardware/software error
HStop statusEmergency stop — machine fully stopped
OClearingFix cause → press RESET
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.