SMART SAFE OPER. SYSTEM ALARM2 (No., Information, )
A safety monitoring function error was detected. No. | Information | Cause --- | --- | --- 1 | Factor (*1) | SBT start impossible | | When making the SBT start signal valid, the test start conditions are not met. 2 | Axis name | SBT warning 1 | | In external brake test pattern 1, axis movement amount exceeded the permissible value. 5 | Axis name | SBT warning 4 | | In motor brake test pattern 1, axis movement amount exceeded the permissible value. 6 | Axis name | SBT warning 5 | | In motor brake test pattern 2, axis movement amount exceeded the permissible value. 7 | Axis name | SBT warning 6 | | In motor brake test pattern 3, axis movement amount exceeded the permissible value. *1 Factor | Description --- | --- 0001 | System during automatic operation existing 0002 | No in the in-position state 0003 | In the servo off state 0004 | In the current limited state 0005 | Slave axis in synchronous control 0006 | In the superimposition control state 0007 | In the arbitrary axis exchanged control state 0008 | In the mixed control state 0009 | SBT parameter error 000A | Reference point not established 000B | Corresponding to the SBT exclusive conditions 000C | Slave axis SBT invalid 000D | Slave axis SBT start impossible 000E | In the slave axis independent control method
- 1Contact the nearest Mazak Technical Center or Technology Center.