CRITICALAlarm code
1106

SAFETY SHIELD FAILURE (Cause, Alarm No., )

What it means

If the processing load of the PC is too high, it may not be possible to update the model properly. A press of the RESET key returns operation to a normal state, thus allowing interference checks to be performed properly. 1. Creation of the model has failed. 2. The interference check process has not been performed properly. 3. An NC-PC communications error (time-out error) has occurred. 4. An illegal access has been detected in processing at the NC side. 5. Preparation of the safety shield has not completed normally because an alarm occurred during preparation of the safety shield. * For causes 1 to 4, the alarm No. given as the argument is not effective.

What to do
  1. 1Review and correct the parameter and model data.
  2. 2Then press the RESET key.
  3. 3If this does not clear the alarm status, turn power off and then back on.
  4. 4If the alarm is not caused by software or hardware fault, pressing the RESET key to update the model may clear the alarm.
  5. 5If the alarm cannot be cleared, contact the nearest Mazak Technical Center or Technology Center. * For cause 5, take the necessary action according to the corrective action for the alarm number.
Codebook — decoded
BError typeRegistered Data — program or tool data error
LStop statusOperation continued — machine still running
NClearingFix cause → Power OFF → Power ON
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.