NOTICEAlarm code
1115

AXIS NUMBER ERROR (No., )

What it means

The Tx-/Ty-/Tz-axis was selected in the manual mode while in the conditions described below. Or, the Tx-/Ty-/Tz-axis was selected during manual handle pulse interruption. No. | Cause --- | --- 0 × 00000001 | The axis number specified for K114 (or K226) as the horizontal axis of the orthogonal coordinate system does not exist in the control path. Or, the axis is not a linear axis. 0 × 00000002 | The axis number specified for K115 (or K227) as the vertical axis of the orthogonal coordinate system does not exist in the control path. Or, the axis is not a linear axis. 0 × 00000004 | The axis number specified for K116 (or K228) as the height axis of the orthogonal coordinate system does not exist in the control path. Or, the axis is not a linear axis. 0 × 00000008 | The axis number specified for K121 (or K230) as the first rotary axis does not exist in the control path. Or, the axis is not a rotary axis. 0 × 00000010 | The axis number specified for K125 (or K234) as the second rotary axis does not exist in the control path. Or, the axis is not a rotary axis. 0 × 00000020 | The first digit (direction of the first rotary axis) of the value specified for K117 (or K229) as the direction of rotation of the rotary axis is incorrect. 0 × 00000040 | The second digit (direction of the second rotary axis) of the value specified for K117 (or K229) as the direction of rotation of the rotary axis is incorrect. 0 × 00000080 | The machine type set for K113 (or K225) is incorrect.

What to do
  1. 1Set a correct value for parameters K113 to K117, K121, K125 (or parametersK225 to K230, K234).
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
K (L)Stop statusunspecified
OClearingFix cause → press RESET
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →