ILLEGAL OPE (SAFETY SHIELD) (Cause, )
The operations that make interference checking impossible were performed during automatic operation when the INTELLIGENT SAFETY SHIELD function was valid. The values of “Cause” denote the causes below. 1: After an EIA modal search under the invalid status of the INTELLIGENT SAFETY SHIELD in automatic operation mode, the Automatic Operation INTELLIGENT SAFETY SHIELD function was made valid in an attempt to start automatic operation. 2: Following completion of the EIA modal search, manual operation mode was selected and after the axis was moved to a position different from that before the search, memory mode was reselected and a restart operation was attempted. 3: An attempt was made to start the MDI operation at the same time for both the upper and the lower turret.
- 1Confirm the cause of the alarm.
- 2Also, avoid performing the corresponding operations when the Automatic Operation INTELLIGENT SAFETY SHIELD function is valid.