NOTICEAlarm code
1127

INVALID SAFETY SHIELD

What it means

The INTELLIGENT SAFETY SHIELD for automatic operation has been canceled. 1. With the INTELLIGENT SAFETY SHIELD being valid for automatic operation, a command which is not compatible with interference check was executed. 2. With the INTELLIGENT SAFETY SHIELD being valid for automatic operation, an attempt was made to start a program stored in the storage areas for Hard Disk operation, Ethernet operation, and IC Card operation, or a program prepared for Tape operation.

What to do
  1. 1Tap the alarm clear button to clear the alarm.
  2. 2Be all the more cautious of allowing interference because the INTELLIGENT SAFETY SHIELD is not working.
Codebook — decoded
BError typeRegistered Data — program or tool data error
LStop statusOperation continued — machine still running
SClearingTap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.