CRITICALAlarm code
1155

G124 MOTION RANGE EXCEEDED (Axis name, )

What it means

1. The position of the fundamental axis or parallel axis was outside the movement range upon specifying G124. 2. The fundamental axis or parallel axis has moved beyond the specified movement range in the G124 mode.

What to do
  1. 11.
  2. 2Move the fundamental axis and parallel axis inside their movement ranges before specifying G124.
  3. 32.
  4. 4Correct the program so that the axis concerned move within the movement range.
Codebook — decoded
BError typeRegistered Data — program or tool data error
KStop statusFeed hold — feed stopped, machine ready
PClearingPress RESET to clear
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.