CRITICALAlarm code
123

SP ROT. FLUCT. SETTING ERROR (Alarm No., )

What it means

Alarm No. | Cause --- | --- &0000 0001 | When specifying the M code for enabling the spindle speed fluctuation synchronous mode, a spindle that was already in the spindle speed fluctuation synchronous mode in another control path was specified. &0000 0002 | When specifying the M code for enabling the spindle speed fluctuation synchronous mode, the specified spindle or NC axis did not exist. &0000 0004 | When specifying the M code for enabling the spindle speed fluctuation, a spindle whose spindle speed fluctuation was already enabled in another control path was specified. &0000 0008 | When specifying the M code for enabling the spindle speed fluctuation, the specified spindle or NC axis did not exist. &0000 0010 | The spindle whose spindle speed fluctuation is enabled does not match the spindle encoder number or the spindle specified for the constant surface speed control.

What to do
  1. 1Review the setting.
Codebook — decoded
BError typeRegistered Data — program or tool data error
KStop statusFeed hold — feed stopped, machine ready
PClearingPress RESET to clear
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.