CRITICALAlarm code
125
ILLEGAL AXIS EXISTS
What it means
During reference-point return, the proximity-point detection limit switch has overrun the position in which the watchdog is mounted.
What to do
- 1Either extend the length of the proximity-point watchdog or reduce the reference-point returning speed.
- 2After that, carry out the zero-point returning operation once again.
Codebook — decoded
EError typeNC Equipment — system hardware/software error
HStop statusEmergency stop — machine fully stopped
OClearingFix cause → press RESET
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →