NOTICEAlarm code
1269

B AXIS ROTATION INHL.(DOOR/CV)

What it means

A B-axis rotation command was specified with the machine setup switch set at the “0” (OFF) position and the front door open. A B-axis rotation command was specified with the LBB clamper extended.

What to do
  1. 1Close the front door and retract the LBB clamper before specifying the B-axis rotation command.
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
LStop statusOperation continued — machine still running
P, SClearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.