NOT ACTIVE PROGRAM
1. This alarm indicates that the machine-operating program and the program selected on the PROGRAM (MAZATROL) display differ during execution of the workpiece transfer storage function or the program selected on the PROGRAM (MAZATROL) display differ during execution of the workpiece transfer storage function on the PROGRAM (MAZATROL) display. 2. When the directory selection function was enabled (parameter US1 bit 4 = 1) or the project function was enabled (parameter US1 bit 5 = 1), a work number that had the same name as the work number to be executed in automatic operation from the WORK No. SELECT window but was in a different operation area was selected for WORK No. in the COMPARISON STOP window or for SUB PROG. No. in the RESTART (EIA/ISO) window.
- 11.
- 2Match the machine-operating program and the program selected on the PROGRAM (MAZATROL) display.
- 32.
- 4Select the work number to be executed in automatic operation.