NOTICEAlarm code
1470
INCORRECT DESIGNATED DATA (Note)
What it means
Note : −1 : Data in the error file for space error compensation to be transferred to the NC unit does not match the machine configuration. −2 : Error components in the error file for space error compensation have exceeded the specification (single direction: 128 points, both directions: 64 points). −3 : Data in the error file for space error compensation is illegal.
What to do
- 1Take action below against respective causes described above. −1 : Input the data measured on the corresponding machine. −2 : Make measurements again so that the number of measurement points for each error component will not be greater than 128 points (single direction) or 64 points (both directions). −3 : Match the file format (single direction/both directions) of error data with the valid mode (single direction/both directions).
- 2If the problem is not solved even after the action above, contact the nearest Mazak Technical Center or Technology Center.
Codebook — decoded
BError typeRegistered Data — program or tool data error
LStop statusOperation continued — machine still running
SClearingTap alarm clear button