NOTICEAlarm code
1494

CANNOT EDIT SMC DATA (No., )

What it means

SMC data operation is performed while the SMC data editing is not allowed or for the data items that cannot be edited. No. | Cause --- | --- 0 | The edit menu was selected although the SMC data was not selected. 1 | An attempt was made to edit SMC No. 0. 2 | An attempt was made to edit the locked SMC data. Or, the locked SMC data is specified as the destination of transfer. 3 | An attempt was made to edit the SMC data currently used in operation. Or, the SMC data currently used in operation was specified as the destination of transfer. 4 | The “SMC data addition” operation was performed by selecting the SMC data that is already registered.

What to do
  1. 1Edit the SMC data after arranging the conditions that allow editing of the SMC data.
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
LStop statusOperation continued — machine still running
SClearingTap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →