NOTICEAlarm code
1706
UNCUT EXIST (WNo., UNo., SNo.)
What it means
In intelligent pocket milling (IPM), the engage angle is too large for the tool nose R.
What to do
- 1Change the programmed engage angle smaller.
- 2Or, make the uncut check function invalid by setting E108 bit 1 = 0.
Codebook — decoded
BError typeRegistered Data — program or tool data error
LStop statusOperation continued — machine still running
SClearingTap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.