CRITICALAlarm code
1806

ILLEGAL CMD TILTED PLANE CMD (WNo., NNo., BNo.)

What it means

A command (G-command or T-command) that cannot be used for inclined-surface machining has been specified during inclined-surface machining.

What to do
  1. 1Cancel inclined-surface machining before executing a G-command or T-command that cannot be used during inclined-surface machining.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.