CRITICALAlarm code
1811
CANNOT USE G43.1 (WNo., NNo., BNo.)
What it means
“Tool length correction in the tool axial direction” has been specified in the mode that does not permit that command.
What to do
- 1Cancel modes that cannot be used with “Tool length correction in the tool axial direction”.
Codebook — decoded
BError typeRegistered Data — program or tool data error
LStop statusOperation continued — machine still running
OClearingFix cause → press RESET
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →