CRITICALAlarm code
1831

ILLEGAL CHOPPING CONDITION (WNo., NNo., BNo.)

What it means

1. The top dead point and the bottom dead point are the same. 2. The chopping feed rate command specifies zero. 3. The chopping command is given in the chopping command inhibiting mode. 4. An illegal value (other than 0 to 2) is set for the chopping offset method. 5. An illegal value (other than 0 to 7) is set for the chopping offset number. 6. The chopping record M-code is issued when the offset update method is selected. 7. An overflow occurs when writing the chopping speed value.

What to do
  1. 1Take action below to remove the cause, and press the RESET key or tap the alarm clear button.
  2. 21.
  3. 3Review the command for the top dead point or bottom dead point.
  4. 42.
  5. 5Review the chopping feed rate command.
  6. 63.
  7. 7Issue the chopping command in the chopping command possible mode.
  8. 84.
  9. 9Set a correct value (0 to 2) for the chopping offset method.
  10. 105.
  11. 11Set a correct value (0 to 7) for the chopping offset number.
  12. 126.
  13. 13Do not issue the chopping record M-code when the offset update method is selected.
  14. 147.
  15. 15Specify the chopping speed value so that an overflow will not occur during writing.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →