CRITICALAlarm code
1835
FILE ACCESS ERROR (Cause, )
What it means
1. Before reading the program for the control path in which the alarm occurred, a process was executed in response to a command specified in another control path. 2. Access to the program file used for the hard disk or Ethernet operation did not complete within the preset time.
What to do
- 11.
- 2Add a queuing command before the following commands.
- 3Cross machining command (G110), C-axis selection M code, synchronization cancellation M code 2.
- 4Set a larger value for parameter SU55 and check if the alarm reoccurs.
- 5When running the machine using Ethernet, review the network environment.
- 6If the problem cannot be solved by these checks, note the numbers in the parentheses and contact the nearest Mazak Technical Center or Technology Center.
Codebook — decoded
GError typeExternal I/O — external I/O unit malfunction
IStop statusReset stop — waiting for reset
PClearingPress RESET to clear
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →