NOTICEAlarm code
184

ILLEGAL OPER IN G54.4 MODE

What it means

An attempt was made in the mode of workpiece placement error correction to perform such an improper operation as follows: 1. Manual interruption 2. Interruption using the manual pulse handle 3. MDI interruption

What to do
  1. 1Do not attempt to perform any of the above operations 1 to 3 in the mode of workpiece placement error correction.
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
LStop statusOperation continued — machine still running
QClearingFix cause → tap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →