NOTICEAlarm code
186

W-THERMAL COMP. OVER LIMIT

What it means

The amount of compensation for workpiece thermal expansion exceeded the effective range of +0.5 to –0.5 mm.

What to do
  1. 1The operation is continued with the amount of error compensation reduced to the limit (+0.5 to –0.5 mm).
  2. 2Change the reference point for workpiece thermal expansion compensation to a point on the workpiece, or execute the workpiece thermal expansion compensation enable/disable command when the tool tip is in close proximity to the workpiece.
Codebook — decoded
BError typeRegistered Data — program or tool data error
LStop statusOperation continued — machine still running
SClearingTap alarm clear button