NOTICEAlarm code
186
W-THERMAL COMP. OVER LIMIT
What it means
The amount of compensation for workpiece thermal expansion exceeded the effective range of +0.5 to –0.5 mm.
What to do
- 1The operation is continued with the amount of error compensation reduced to the limit (+0.5 to –0.5 mm).
- 2Change the reference point for workpiece thermal expansion compensation to a point on the workpiece, or execute the workpiece thermal expansion compensation enable/disable command when the tool tip is in close proximity to the workpiece.
Codebook — decoded
BError typeRegistered Data — program or tool data error
LStop statusOperation continued — machine still running
SClearingTap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →