CRITICALAlarm code
1904
ILLEGAL CMD DURING G2.2/G3.2 (WNo., NNo., BNo.)
What it means
In the involute interpolation mode, an unusable command was specified.
What to do
- 1Cancel involute interpolation before specifying a command that cannot be used in the involute interpolation mode.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
P (S)Clearingunspecified