CRITICALAlarm code
191
FILE SYSTEM I/O ERROR (Alarm No., )
What it means
An internal error(s) has occurred during program data change by the function of VFC, MMS etc.
What to do
- 1After checking the entire data of the program being executed, tool data, tool file, parameters, etc., save the data using the data I/O operation and then Contact the nearest Mazak Technical Center or Technology Center.
Codebook — decoded
EError typeNC Equipment — system hardware/software error
IStop statusReset stop — waiting for reset
PClearingPress RESET to clear
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.