CRITICALAlarm code
192

EXECUTION IMPOSSIBLE (WNo., UNo., SNo.)

What it means

1. A measurement operation was attempted although there is no FRM unit. 2. Coordinate measurement was executed from the FRM unit set as the center of table rotation. 3. Measurement of a tool other than a milling tool was attempted with laser measurement. 4. Offsetting of a tool other than a turning tool was attempted using measurement of O.D., I.D, single-side O.D., or single-side I.D. in a workpiece measurement unit. 5. Offsetting other than tool radius offset was attempted for a milling tool using measurement of groove width, protrusion width, I.D. protrusion width, or I.D. groove width in a workpiece measurement unit. 6. The barrier teaching function was activated while running a program stored outside the memory operation range or while there was an active barrier alarm during MDI operation. 7. An axis command for the driven axis was specified with the axis set in the synchronized operation mode. 8. The override variable thread cutting function was activated while position data is memorized using the rethreading function. 9. A winding that does not support the override variable thread cutting function is selected.

What to do
  1. 11.
  2. 2Set the FRM unit.
  3. 32.
  4. 4Review the setting of the FRM unit.
  5. 53.
  6. 6Measure only milling tools with laser measurement.
  7. 74.
  8. 8Select a turning tool.
  9. 95.
  10. 10Offset only the tool radius for a milling tool.
  11. 116.
  12. 12Do not use the barrier teaching function for programs other than the ones stored in the memory operation range.
  13. 137.
  14. 14Specify the command after canceling the synchronization of the axes.
  15. 158.
  16. 16Clear the memorized position data before using the override variable thread cutting function.
  17. 179.
  18. 18Select a winding that supports the function.
Codebook — decoded
EError typeNC Equipment — system hardware/software error
IStop statusReset stop — waiting for reset
P (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.