CRITICALAlarm code
194

NO TOOL DATA IN PROGRAM (WNo., UNo., SNo.)

What it means

An internal error(s) has occurred when surface speed or feedrate changing by VFC function was under way.

What to do
  1. 1After checking the entire data of the program being executed, tool data, tool file, parameters, etc., save the data using the data I/O operation (floppy disk) and then contact the nearest Mazak Technical Center or Technology Center.
Codebook — decoded
EError typeNC Equipment — system hardware/software error
IStop statusReset stop — waiting for reset
PClearingPress RESET to clear
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.