CRITICALAlarm code
1991

NOT POSSIBLE CROSS MACHINING (WNo., NNo., Cause)

What it means

During the tool path check, the system in which the crossing command was set and/or the remote system for which the crossing command was to be executed has been set to the following status: 1: The specified axis does not exist in the remote system. 2: The local system is specified as the system for which the crossing command was to be executed. 4: A crossing control command is set for the axis currently undergoing the crossing command. 16: The G110 command is set when the local system/remote system is in the modal environment that does not allow crossing control. 32: The crossing control command is set under the prohibited status of recalculation.

What to do
  1. 1Review and correct the program.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.