CRITICALAlarm code
201
CHILLER MALFUNCTION
What it means
Something is wrong with the hydraulic chiller unit.
What to do
- 11.
- 2Check the chiller unit filter for clogging.
- 32.
- 4Check the chiller unit in accordance with its operating manual.
- 53.
- 6Check if the thermal relays of the circuit breakers and electromagnetic switches in the chiller unit control panel have tripped.
- 7If a tripped circuit breaker is found, turn it back on.
- 8If the thermal relay of an electromagnetic switch is found to have tripped, press the RESET button of the tripped thermal relay.
- 9If the alarm is not released, contact the nearest Mazak Technical Center or Technology Center.
Codebook — decoded
FError typeMachine (PLC) — machine failure
KStop statusFeed hold — feed stopped, machine ready
OClearingFix cause → press RESET
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.