CRITICALAlarm code
212

MAGAZINE DRUM MALFUNCTION

What it means

The alarm for the magazine rotating servo driver was raised.

What to do
  1. 11.
  2. 2Press the RESET key.
  3. 32.
  4. 4Turn the main power disconnect switch off and then back on.
  5. 5Then rotate the magazine manually to check for interference of the tools.
  6. 6If the alarm is not released, contact the nearest Mazak Technical Center or Technology Center.
Codebook — decoded
CError typeServo — servo control mechanism malfunction
JStop statusSingle-block stop — stopped at a block
NClearingFix cause → Power OFF → Power ON
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.