WARNINGAlarm code
227
SIMULTANEOUS M CODE OPERATION
What it means
M codes that cannot be handled simultaneously have been specified at the same time. (Ex.: Simultaneous entry of M3 and M4.)
What to do
- 1Correct the program.
Codebook — decoded
BError typeRegistered Data — program or tool data error
KStop statusFeed hold — feed stopped, machine ready
QClearingFix cause → tap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.