NOTICEAlarm code
282
NO ORIENT (ATC ARM POS. ERROR)
What it means
When the ATC arm was not in its reference position, a milling spindle orient command was entered.
What to do
- 1Move the ATC arm to its reference position in a manual operation mode.
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
LStop statusOperation continued — machine still running
OClearingFix cause → press RESET
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.