NOTICEAlarm code
295
NO TOOL SELECT(ARM/SFT POS ERR)
What it means
1. An attempt was made to manually operate the ATC arm when the tool carrier was not at the ATC side position. 2. The ATC arm was manually operated during tool carrier operation. 3. The magazine was rotated while the tool shifter was at the magazine side position.
What to do
- 11.
- 2Move the tool carrier to the ATC side position.
- 32.
- 4Perform manual operation of the ATC arm only after tool carrier operation has been stopped.
- 53.
- 6Move the tool shifter to a position other than the magazine side side position before performing magazine operation.
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
LStop statusOperation continued — machine still running
OClearingFix cause → press RESET
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.