CRITICALAlarm code
314

CHUCK SENSOR MALFUNCTION

What it means

Both the open end sensor and the close end sensor were turned on simultaneously on a machine equipped with chuck open/close confirmation sensors.

What to do
  1. 11.
  2. 2Check if the chuck holds the workpiece correctly.
  3. 32.
  4. 4If the diameter of the workpiece currently inserted in the chuck is different from that of the previous workpiece, or if the stroke of the chuck jaw has been changed, check also if the chuck opening/closing sensor works normally when a workpiece is set in the chuck.
  5. 5If necessary, adjust the position.
Codebook — decoded
FError typeMachine (PLC) — machine failure
KStop statusFeed hold — feed stopped, machine ready
OClearingFix cause → press RESET
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →