NOTICEAlarm code
419

AUTO TAP PROCESS IMPOSSIBLE

What it means

1. The pitch or other data cannot be automatically set because of incorrectness of the tap nominal diameter in the tapping-unit data. 2. Although the text file is referred to for the pipe tap auto-setting (D95 bit 0 = 1), the auto-setting function cannot be executed since the auto-setting text file (Pipescdt. txt) is incorrect or contains no data.

What to do
  1. 11.
  2. 2Check and correct the tapping-unit data and tapping-tool sequence data of the program.
  3. 32.
  4. 4Check and correct the auto-setting text file (Pipescdt. txt).
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
LStop statusOperation continued — machine still running
SClearingTap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.