NOTICEAlarm code
428
MEMORY PROTECT (AUTO OPERATION)
What it means
An attempt has been made to input unallowable data on a display (such as the TOOL DATA display) during automatic operation.
What to do
- 1Input allowable data only after placing the NC unit in its reset state or after changing the current mode over to another mode.
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
LStop statusOperation continued — machine still running
SClearingTap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.