CRITICALAlarm code
43

SPINDLE MALFUNCTION 2

What it means

The spindle (NC reset level) is abnormal. The inertia on the spindle is excessive.

What to do
  1. 1Contact the nearest Mazak Technical Center or Technology Center.
  2. 2Note : If this alarm is displayed after replacing the workpiece, the situation may be improved by executing the inertia estimation function.
Codebook — decoded
CError typeServo — servo control mechanism malfunction
HStop statusEmergency stop — machine fully stopped
OClearingFix cause → press RESET
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →