NOTICEAlarm code
447
PROGRAM ERROR
What it means
A program error(s) has occurred during EIA/ISO restart search.
What to do
- 1The program being searched for includes an error(s).
- 2Perform a tool-path check upon the program contents.
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
LStop statusOperation continued — machine still running
SClearingTap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →