NOTICEAlarm code
488

MEMORY PROTECT (MAGAZINE SETUP)

What it means

Tool data updating operations (such as editing tool data, completing the layout of tools, or downloading data on the DATA I/O display) have been attempted during magazine setup.

What to do
  1. 1Perform tool data updating operations after completing the magazine setup operations.
  2. 2Deselect [MAGAZINE SETUP] relating to visual tool data management.
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
LStop statusOperation continued — machine still running
SClearingTap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.