NOTICEAlarm code
488
MEMORY PROTECT (MAGAZINE SETUP)
What it means
Tool data updating operations (such as editing tool data, completing the layout of tools, or downloading data on the DATA I/O display) have been attempted during magazine setup.
What to do
- 1Perform tool data updating operations after completing the magazine setup operations.
- 2Deselect [MAGAZINE SETUP] relating to visual tool data management.
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
LStop statusOperation continued — machine still running
SClearingTap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.