NOTICEAlarm code
511

PROGRAM DATA NOT SAME (WNo., UNo., SNo.)

What it means

Comparison between the cassette tape or floppy disk contents and the NC data has shown several disparities.

What to do
  1. 11.
  2. 2After correcting the disparities within the machining program, make the comparison once again.
  3. 32.
  4. 4If the disparities exist in data other than machining program data, locate those disparities on each display.
  5. 5Note : This alarm message may be displayed if data is saved prior to automatic operation and then subjected to comparison with that after automatic operation.
  6. 6This is because execution of automatic operation may cause automatic data overriding.
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
LStop statusOperation continued — machine still running
SClearingTap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.