NOTICEAlarm code
519

DATA SIZE EXCEEDED (WNo., Note, )

What it means

The EIA/ISO machining program includes a block that consists of more than 256 characters. (EOB or EOR does not appear within 256 characters.) Note : The number displayed next to the work number is a line number, which corresponds to the number displayed in the lower right section of the PROGRAM display.

What to do
  1. 1Correct the EIA/ISO machining program. (Insert EOB within 256 characters.)
Codebook — decoded
AError typeOperation — wrong key or incorrect operation
LStop statusOperation continued — machine still running
SClearingTap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →