528

FIELDNETWORK SETTING ERROR (Note 1, Note 2, )

What it means

Note : 1. Cause 1: The value at R19974 (field network output data top register) is out of the setting range. 2: The value at R19976 (field network input data top register) is out of the setting range. 3: The value specified at the register R for high-speed data input/output is out of the setting range. 4: The value of parameter F150 is out of the setting range. 2. Field network expansion card type 0: Not connected 1: PROFIBUS-DP unit 2: EtherNet/IP unit

What to do
  1. 11.
  2. 2Review the value at R19974 (field network output data top register).
  3. 32.
  4. 4Review the value at R19976 (field network input data top register).
  5. 53.
  6. 6Review the value at the register R for high-speed data input/output.
  7. 74.
  8. 8Review the value of parameter F150.
Codebook — decoded
EError typeNC Equipment — system hardware/software error
LStop statusOperation continued — machine still running
MClearingPower OFF → fix cause → Power ON
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.