NOTICEAlarm code
528
FIELDNETWORK SETTING ERROR (Note 1, Note 2, )
What it means
Note : 1. Cause 1: The value at R19974 (field network output data top register) is out of the setting range. 2: The value at R19976 (field network input data top register) is out of the setting range. 3: The value specified at the register R for high-speed data input/output is out of the setting range. 4: The value of parameter F150 is out of the setting range. 2. Field network expansion card type 0: Not connected 1: PROFIBUS-DP unit 2: EtherNet/IP unit
What to do
- 11.
- 2Review the value at R19974 (field network output data top register).
- 32.
- 4Review the value at R19976 (field network input data top register).
- 53.
- 6Review the value at the register R for high-speed data input/output.
- 74.
- 8Review the value of parameter F150.
Codebook — decoded
EError typeNC Equipment — system hardware/software error
LStop statusOperation continued — machine still running
MClearingPower OFF → fix cause → Power ON