NOTICEAlarm code
585
CABLE MIS-CONNECTED
What it means
This message implies incorrect cable connection between the host system and the NC unit or implies a power-off status.
What to do
- 1Check if the DNC cables are correctly connected.
- 2Check if the host system is turned on and ready for data transmission/reception.
- 3There may be cases that although a DNC option is provided, DNC itself is not to be used for the time being and thus the DNC cables are not yet connected.
- 4If this is the case, then set the appropriate parameter (DNC26, bit 1) to OFF (0).
- 5This will clear the alarm display.
Codebook — decoded
( , ) GError typeunspecified
LStop statusOperation continued — machine still running
SClearingTap alarm clear button