DNC I/O ERROR

What it means

During use of DNC, processing has been aborted by line noise or other hardware factors. RS-232C communication parameter settings (such as those of the baud-rate, etc.) between the host system and NC unit differ. Timer, number-of-retries or other settings are not correct.

What to do
  1. 1Make line checks and hardware checks of the host system and NC unit.
  2. 2Match the RS-232C communication parameter settings between the host system and NC unit.
  3. 3Set the timer, number-of-retries, or other settings to those of the host system. (Parameters for the NC unit: DNC parameters)