NOTICEAlarm code
593
DNC I/O ERROR
What it means
During use of DNC, processing has been aborted by line noise or other hardware factors. RS-232C communication parameter settings (such as those of the baud-rate, etc.) between the host system and NC unit differ. Timer, number-of-retries or other settings are not correct.
What to do
- 1Make line checks and hardware checks of the host system and NC unit.
- 2Match the RS-232C communication parameter settings between the host system and NC unit.
- 3Set the timer, number-of-retries, or other settings to those of the host system. (Parameters for the NC unit: DNC parameters)
Codebook — decoded
( , ) GError typeunspecified
LStop statusOperation continued — machine still running
SClearingTap alarm clear button
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →