REMOTE I/O INITIALIZE ERROR (No., System, )
An error occurred during remote I/O initialization processing. No. Cause 0 × 01 RIO2.0 control register does not “stop” although RIO2.0 stop was requested. 0 × 02 Cyclic transfer counter is not operating. 0 × 04 In RIO2.0 communication, connection status cannot be obtained. 0 × 08 RIO1.0 communication was conducted using a station number (9 or larger) which is outside the RIO1.0 communication range. 0 × 10 A unit for RIO1.0 communication is connected to the No. 3 system. 0 × 20 Units of more than 17 stations were connected to the No. 3 system. 0 × 40 A safety RIO unit and a unit for RIO1.0 communication are connected to the same system. 0 × 80 The received data of a safety RIO is not updated. 0 × 100 Time-out in obtaining the RIO1.0 communication enabled station information while RIO2.0 communication setting is made.
- 1Contact the nearest Mazak Technical Center or Technology Center.