CRITICALAlarm code
637

STOCK REMOVAL R TOO SMALL (WNo., UNo., SNo.)

What it means

In the line- or face-machining unit, removal allowance R is smaller than finish allowance R.

What to do
  1. 1Review the line- or face-machining unit and increase the value of removal allowance R to a value greater than that of finish allowance R.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified