CRITICALAlarm code
637
STOCK REMOVAL R TOO SMALL (WNo., UNo., SNo.)
What it means
In the line- or face-machining unit, removal allowance R is smaller than finish allowance R.
What to do
- 1Review the line- or face-machining unit and increase the value of removal allowance R to a value greater than that of finish allowance R.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.