CRITICALAlarm code
661
ILLEGAL M CODE (WNo., UNo., SNo.)
What it means
M195 (tool breakage detection start command code) has been set for the M-code unit or for the manual program mode sequence.
What to do
- 1M195 cannot be executed on MAZATROL programs.
- 2Delete that command code from the program.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.