WRONG HEAD ANGLE (WNo., UNo., )
1. A corner-face unit or plane inclination measurement has been designated in unit data other than inclined-plane machining unit data. 2. Table rotational machining has been designated in spite of the fact that the facial angle data in the face definition sequence is not for the top plane. 3. Calibration measurement has been designated for the top plane or an inclined plane. 4. Groove center, hole center, boss center, and step width measurements have been designated for an inclined plane. 5. Machining at the work hand side “↓Z” (B-axis at 90°, approach in the Z-axis) has been specified for the direction of the geometry sequence in coordinate measurement. 6. Machining at the work hand side “↓Z” (B-axis at 90°, approach in the Z-axis) has been specified for the direction of the geometry sequence in workpiece measurement. 7. Measurement at the work hand side has been attempted with the parameter setting of L106 bit5 = 0 (B-axis user-defined angle measurement invalid).
- 11.
- 2A corner-face unit and plane inclination measurement can be designated only for an inclined plane.
- 32.
- 4Table rotational machining can be executed only for the top plane.
- 53.
- 6Calibration measurement is possible only for the side.
- 74.
- 8Only reference plane measurement and plane inclination measurement are possible for inclined planes.
- 95.
- 10Change the direction setting of the geometry sequence in coordinate measurement to “↓X” (B-axis at 90°, approach in the X-axis).
- 11Alternatively, select “↑X”, “−Z”, or “−X” for measurement with the B-axis at 0°.
- 126.
- 13Change the direction setting of the geometry sequence in workpiece measurement to “↓X” (B-axis at 90°, approach in the X-axis).
- 14Alternatively, select “↑X”, “−Z”, or “−X” for measurement with the B-axis at 0°.
- 157.
- 16Change the parameter setting to L106 bit5 = 1.