CRITICALAlarm code
672
ILLEGAL AREA DATA INPUT (WNo., UNo., SNo.)
What it means
In the check surface data of the 3-D machining unit, the setting of the maximum value is smaller than that of the minimum value.
What to do
- 1Review the check surface data, and make corrections so that the setting of the maximum value is equal to or greater than that of the minimum value for each axis.
Codebook — decoded
BError typeRegistered Data — program or tool data error
I (L)Stop statusunspecified
O (S)Clearingunspecified
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →