WARNINGAlarm code
701

DEFINED SHAPE TOO SMALL (WNo., UNo., SNo.)

What it means

The shape compensation clearance with respect to the shape of the endmilling-top is too large; or the tool diameter with respect to the size of the line-inside machining is too large.

What to do
  1. 1Change the shape compensation clearance (parameter E13) to an appropriate value; or use a tool of smaller diameter.
Codebook — decoded
BError typeRegistered Data — program or tool data error
KStop statusFeed hold — feed stopped, machine ready
OClearingFix cause → press RESET
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →