WARNINGAlarm code
702
FIGURE DEFINITION ERROR (WNo., UNo., SNo.)
What it means
1. The input shape is contradictory to logic, that is, the radius of the arc, for example, does not agree with the distance from the center. 2. An attempt was made to execute the smooth chamfering program when CHMF in the end milling slot unit is set to other than 0, when an arc is specified or when the shape sequence is specified in three or more lines.
What to do
- 11.
- 2Such contradiction usually results from arithmetic errors.
- 3Change the radial depth of cut by some micro, or use a tool of smaller diameter.
- 42.
- 5When executing the smooth chamfering program, set a linear shape, whose angle formed with the X-axis is 0 degrees, in two lines (start point line and end point line).
Codebook — decoded
BError typeRegistered Data — program or tool data error
KStop statusFeed hold — feed stopped, machine ready
OClearingFix cause → press RESET
Still faulted after these steps? Do not restart under load — ask the Mazatrol assistant.
Still stuck? Ask the Mazatrol assistant →